| Mikron |
 |
Snap Action, Automatic Reset, Type : LU-10 & LU-11 |
 |
Snap Action, Automatic / Manual Reset, Type : L-20, L-21, L-30 |
 |
Snap Action, Automatic / Manual Reset, Type : LM-1, LM-2 |
 |
Snap Action, Automatic / Manual Reset, Type : L-50, L-51, L-60 |
|
 |
|
|
| LU-10 |
Normally Closed, Automatic Reset |
| LU-11 |
Normally Open, Automatic Reset |
|
| Specifications |
| Voltage Rating |
250 VAC, 50 Hz |
| Current Rating |
60 A |
| Operating Temp. |
60 deg. C - 150 deg. C (In 10 deg. Increments) |
| Tolerance |
+- 5deg. C |
| Differential |
5 deg. C to 50 deg. C |
| Terminal |
Push On 4.8 x 0.5 mm |
| Use Heat Sink Compound on sensing surface before mounting Thermal Cut-Out. |
| Use Push On terminals only. Do not Solder the terminals. |
|
|
 |
 |
|
|
| L-20 |
Normally Closed, Automatic Reset |
| L-21 |
Normally Open, Automatic Reset |
| L-30 |
Normally Closed, Manual Reset |
|
| Specifications |
| Voltage Rating |
250 VAC, 50 Hz |
| Current Rating |
10 A |
| Operating Temp. |
60 deg. C - 150 deg. C (In 10 deg. Increments) at no load. |
| Tolerance |
+- 5deg. C |
| Differential |
5 deg. C to 50 deg. C |
| Terminal |
Push On 6.3 x 0.8 mm |
| Contacts |
Double Brake |
| Preferably use Heat Sink Compound on sensing surface before mounting Thermal Cut-Out. |
| Use Push On terminals only. Do not Solder the terminals. |
|
|
 |
 |
|
|
| LM-1 |
Normally Closed, Automatic Reset |
| LM-2 |
Normally Open, Automatic Reset |
| LM-5 |
Normally Closed, Manual Reset |
| Note : LM-5 can be reset manually only when Temperature drops 30% below its Operating Temperature.
|
|
| Specifications |
| Voltage Rating |
250 VAC, 50 Hz |
| Current Rating |
80 A |
| Operating Temp. |
50 deg. C - 150 deg. C (In 10 deg. Increments). |
| Tolerance |
+- 5deg. C |
| Differential |
5 deg. C to 50 deg. C |
| Terminal |
Push On 4.8 x 0.8 mm |
| Contacts |
Double Brake |
| Use Heat Sink Compound on sensing surface before mounting Thermal Cut-Out. |
| Use Push On terminals only. Do not Solder the terminals. |
|
|
 |
 |
|
|
| L-50 |
Normally Closed, Automatic Reset |
| L-51 |
Normally Open, Automatic Reset |
| L-60 |
Normally Closed, Manual Reset |
| Note : L-60 can be reset manually only when Temperature drops 30% below its Operating Temperature.
|
|
| Specifications |
| Voltage Rating |
250 VAC, 50 Hz |
| Current Rating |
16 A |
| Operating Temp. |
60 deg. C - 150 deg. C (In 10 deg. Increments). |
| Tolerance |
+- 5deg. C |
| Differential |
5 deg. C to 50 deg. C |
| Terminal |
Screw Type |
| Contacts |
Double Brake |
| Use Heat Sink Compound on sensing surface before mounting Thermal Cut-Out. |
|
|
 |